{"product_id":"26u-outdoor-network-cabinet-enclosure-ip66-rated-weatherproof-for-telecom-fiber-and-server-equipment-stainless-steel-with-air-conditioning-600mm-x-800mm-24-x-32-floor-wall-mount-stv-hc-26u600","title":"STURDX Climate Series™ 26U IP66 Weatherproof Stainless Steel Outdoor Network Cabinet with Air Conditioner | 24\" × 32\" (600 × 800 mm) | 19-Inch Rack Enclosure","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSTURDX Climate Series™ 26U IP66 Weatherproof Stainless Steel Outdoor Network Cabinet with Air Conditioner (24\" × 32\" \/ 600 × 800 mm)\u003c\/strong\u003e is engineered for outdoor installations where \u003cstrong\u003ecorrosion resistance, additional equipment depth, and precise thermal management\u003c\/strong\u003e are essential for long-term system reliability. With \u003cstrong\u003e26U\u003c\/strong\u003e of rack capacity inside a \u003cstrong\u003e24-inch × 32-inch (600 × 800 mm)\u003c\/strong\u003e enclosure, it provides the ideal balance between compact installation width and the additional interior depth required by modern networking and industrial equipment.\u003c\/p\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003e304 stainless steel\u003c\/strong\u003e with insulated double-wall construction, the enclosure is designed for environments exposed to salt spray, chemical vapors, humidity, washdowns, and airborne contaminants. The deeper cabinet profile provides valuable clearance behind rack-mounted equipment, allowing cleaner cable routing, improved service accessibility, and easier installation of enterprise switches, industrial computers, fiber distribution hardware, and power systems. For the harshest environments, \u003cstrong\u003e316 stainless steel\u003c\/strong\u003e is available upon request.\u003c\/p\u003e\n\u003cp\u003eWhat sets the Climate Series™ apart is the \u003cstrong\u003eSTURDX Hybrid Cooling Ready™\u003c\/strong\u003e architecture. Every enclosure is factory-prepared for closed-loop air conditioning while incorporating concealed fan provisions protected by removable blanking plates. This unique configuration allows owners to introduce optional filtered fan ventilation later if site conditions change—without cutting, welding, or replacing the enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTURDX Climate Series™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSTX-CL-26U60802XD-SS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e26U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA-310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd\u003e23.6\" × 31.5\" (600 × 800 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003e304 Stainless Steel \u003cem\u003e(316 Stainless Steel Available Upon Request)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eInsulated Double-Wall Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEMA\u003c\/td\u003e\n\u003ctd\u003eSuitable for NEMA 4X Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eAir Conditioner Ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Rails\u003c\/td\u003e\n\u003ctd\u003eFour Adjustable Rails Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor Switch\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor Stopper\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Glands\u003c\/td\u003e\n\u003ctd\u003eIP68 Rated Included \u003cem\u003e(316 Stainless Steel Available Upon Request)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry\u003c\/td\u003e\n\u003ctd\u003eBottom Knockouts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoors\u003c\/td\u003e\n\u003ctd\u003eLockable Front \u0026amp; Rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003eFloor Mounting Base Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifting\u003c\/td\u003e\n\u003ctd\u003eFactory-Installed Lifting Eyebolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eStandard Features\u003c\/h1\u003e\n\u003cp\u003eEvery STURDX Climate Series™ cabinet includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e304 stainless steel enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulated construction for improved thermal performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSTURDX Hybrid Cooling Ready™ platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP66 weatherproof protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for NEMA 4X applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory-prepared air conditioner opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCovered fan openings with removable blanking plates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour adjustable rack mounting rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoor switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoor stopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP68 cable glands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBottom cable entry knockouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLockable front and rear doors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePolyurethane sealing gasket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated grounding system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFloor mounting base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory-installed lifting eyebolts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eAir Conditioning Solutions\u003c\/h1\u003e\n\u003cp\u003eEvery Climate Series™ enclosure can be configured with the cooling system best suited to your installation.\u003c\/p\u003e\n\u003ch3\u003eStandard 110V \/ 60Hz Enclosure Air Conditioners\u003c\/h3\u003e\n\u003cp\u003eAvailable with either \u003cstrong\u003egalvanized\u003c\/strong\u003e or \u003cstrong\u003estainless steel\u003c\/strong\u003e housings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Capacity\u003c\/th\u003e\n\u003cth\u003eApprox. BTU\/hr\u003c\/th\u003e\n\u003cth\u003eFeatures\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e300W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e≈1,000 BTU\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooling • Heating • Dehumidifier • Remote Access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e600W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e≈2,000 BTU\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooling • Heating • Dehumidifier • Remote Access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2000W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e≈8,000 BTU\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooling • Heating • Dehumidifier • Remote Access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCooling Only + Remote Access models are also available.\u003c\/p\u003e\n\u003ch3\u003eHigh-Capacity Systems\u003c\/h3\u003e\n\u003cp\u003eFor larger installations, STURDX also supplies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e220V \/ 60Hz models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling capacities up to \u003cstrong\u003e6000W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to approximately \u003cstrong\u003e19,000 BTU\/hr\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur engineers can help determine the appropriate cooling capacity based on your installed equipment.\u003c\/p\u003e\n\u003ch3\u003eMade in USA Cooling Systems\u003c\/h3\u003e\n\u003cp\u003eSTURDX also offers \u003cstrong\u003eMade in USA IP66 stainless steel enclosure air conditioners\u003c\/strong\u003e for projects requiring \u003cstrong\u003eBABA compliance\u003c\/strong\u003e, domestic manufacturing, or higher environmental protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProtecting Deeper Equipment in Corrosive Outdoor Environments\u003c\/h1\u003e\n\u003cp\u003eMany outdoor infrastructure projects combine deeper networking hardware with harsh environmental exposure. Enterprise switches, industrial servers, battery backup systems, fiber distribution equipment, and communication gateways all require additional rear clearance while operating within tightly controlled temperatures.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e24\" × 32\" (600 × 800 mm)\u003c\/strong\u003e Climate Series™ enclosure addresses both challenges. Its corrosion-resistant stainless steel construction protects against aggressive environmental conditions, while the additional cabinet depth improves cable routing, equipment spacing, and technician accessibility. The result is a cleaner installation that is easier to maintain and better prepared for future system expansion.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSTURDX Hybrid Cooling Ready™\u003c\/h1\u003e\n\u003cp\u003eUnlike traditional outdoor enclosures that commit users to a single cooling method, the Climate Series™ is designed to evolve with your project.\u003c\/p\u003e\n\u003cp\u003eEvery cabinet ships configured for sealed air-conditioned operation, while removable blanking plates preserve the option to install filtered fan ventilation in the future.\u003c\/p\u003e\n\u003cp\u003eThis flexibility can be valuable when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment is upgraded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal loads change\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeasonal temperatures vary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance is being performed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuture operating requirements evolve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Description\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSTURDX Climate Series™ 26U Stainless Steel Outdoor Network Cabinet\u003c\/strong\u003e provides a premium climate-controlled solution for networking, industrial automation, electrical distribution, and communication systems operating in corrosive outdoor environments.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e24\" × 32\" (600 × 800 mm)\u003c\/strong\u003e footprint delivers the additional installation depth required for modern enterprise equipment while maintaining a compact cabinet width suitable for space-limited sites. Combined with insulated double-wall construction, IP66 weatherproof protection, and corrosion-resistant stainless steel, it offers outstanding long-term reliability for mission-critical outdoor infrastructure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTypical Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCoastal Telecommunications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine Communications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnterprise Network Infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber Optic Distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater \u0026amp; Wastewater Treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood \u0026amp; Beverage Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical Processing Plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility Communication Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRenewable Energy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmart Grid Infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransportation Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecurity \u0026amp; Surveillance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEdge Computing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor Control Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMission-Critical Communications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhy choose a climate-controlled stainless steel 24\" × 32\" enclosure?\u003c\/h3\u003e\n\u003cp\u003eIt combines superior corrosion resistance with additional installation depth, making it ideal for deeper networking equipment operating in demanding outdoor environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat is STURDX Hybrid Cooling Ready™?\u003c\/h3\u003e\n\u003cp\u003eSTURDX Hybrid Cooling Ready™ is our factory-prepared cooling platform that allows every Climate Series™ cabinet to operate as a sealed air-conditioned enclosure while remaining ready for optional filtered fan ventilation if future operating conditions require it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWhich air conditioner capacities are available?\u003c\/h3\u003e\n\u003cp\u003eStandard enclosure air conditioners are available in \u003cstrong\u003e300W, 600W, and 2000W\u003c\/strong\u003e capacities, with larger \u003cstrong\u003e220V systems up to 6000W\u003c\/strong\u003e also available for high-performance outdoor applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eAre stainless steel air conditioners available?\u003c\/h3\u003e\n\u003cp\u003eYes. Standard enclosure air conditioners are available with \u003cstrong\u003estainless steel housings\u003c\/strong\u003e, and STURDX also offers \u003cstrong\u003eMade in USA IP66 stainless steel air conditioners\u003c\/strong\u003e for customers requiring BABA-compliant or domestically manufactured cooling systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eIs 316 stainless steel available?\u003c\/h3\u003e\n\u003cp\u003eYes. Standard production uses \u003cstrong\u003e304 stainless steel\u003c\/strong\u003e, while \u003cstrong\u003e316 stainless steel\u003c\/strong\u003e is available for offshore, coastal, marine, and aggressive chemical environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eHow does the deeper cabinet improve equipment reliability?\u003c\/h3\u003e\n\u003cp\u003eAdditional depth reduces cable congestion, improves rear equipment access, promotes more uniform conditioned airflow, and simplifies maintenance without increasing cabinet width.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDoes the cabinet include lifting eyebolts?\u003c\/h3\u003e\n\u003cp\u003eYes. Factory-installed lifting eyebolts simplify transportation, unloading, crane handling, and positioning during installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCan STURDX customize this enclosure?\u003c\/h3\u003e\n\u003cp\u003eYes. Climate Series™ cabinets can be customized with different dimensions, 304 or 316 stainless steel construction, electrical integration, cable entry locations, OEM branding, enclosure cooling systems, mounting accessories, and application-specific configurations for virtually any outdoor networking, industrial, or utility application.\u003c\/p\u003e","brand":"STURDX ","offers":[{"title":"Default Title","offer_id":54163232915735,"sku":"STX-CL-26U60802XD-SS","price":5400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/4523\/0615\/files\/stainless-network-cabinet-with-integrated-door-cooling.webp?v=1786697408","url":"https:\/\/www.serverrackcabinets.com\/products\/26u-outdoor-network-cabinet-enclosure-ip66-rated-weatherproof-for-telecom-fiber-and-server-equipment-stainless-steel-with-air-conditioning-600mm-x-800mm-24-x-32-floor-wall-mount-stv-hc-26u600","provider":"STURDX ","version":"1.0","type":"link"}