Filters
144 products
Outdoor Network & Telecom Cabinets – IP66 Weatherproof, Pole, Wall & Floor Mount
STURDX outdoor network and telecom cabinets protect routers, switches, fiber, CCTV recorders, PoE gear and power equipment in places a standard server rack cannot go. Every cabinet is IP66 rated against dust and powerful water jets, built from stainless or galvanized steel, and available from compact 5U pole-mount boxes to 42U floor-standing enclosures with optional air conditioning.
What Is an Outdoor Network Cabinet?
An outdoor network cabinet (also called an outdoor telecom cabinet or weatherproof rack enclosure) is a sealed, lockable 19-inch rack enclosure designed for installation outside a building. It keeps rain, dust, insects and tampering away from active equipment while managing heat with vents, fan modules or an integrated A/C unit.
Shop Outdoor Cabinets by Rack Size
| Rack size | Approx. height | Footprint options (W x D) | Mounting |
|---|---|---|---|
| 5U | 14 in | 15 x 16 in (10-inch rack) | Pole, wall |
| 7U | 16 in | 24 x 10, 24 x 18, 24 x 24 in | Pole, wall, floor |
| 9U | 25 in | 24 x 18, 24 x 24 in | Pole, wall, floor |
| 12U | 31 in | 24 x 18, 24 x 24 in | Pole, wall, floor |
| 16U | 37.5 in | 24 or 32 in wide; 24, 32, 39 in deep | Wall, floor |
| 20U | 40 in | 24 or 32 in wide; 24, 32, 39 in deep | Pole, wall, floor |
| 26U | 56 in | 24 or 32 in wide; 32, 39 in deep | Wall, floor |
| 32U | 60 in | 24 or 32 in wide; 24, 32, 39 in deep | Floor (pad) |
| 42U | 78 in | 24 or 32 in wide; 24, 32, 39 in deep | Floor (pad) |
Mounting options vary by model; check each product page for the exact configuration.
Choose Your Series
- Essential Series: passive IP66 outdoor network cabinets for routers, switches, fiber splice and patch gear.
- Climate Series: the same weatherproof enclosure with a factory-fitted air conditioner for hot climates and high heat loads. See all outdoor cabinets with A/C.
- Outdoor Security Series: slim 5U and 7U pole mount cabinets for CCTV, NVRs and PoE switches.
Stainless Steel vs. Galvanized Steel
| Stainless steel | Galvanized steel | |
|---|---|---|
| Corrosion resistance | Highest; ideal for coastal, marine and chemical sites | Very good for most inland sites |
| Look | Brushed metal | Light gray / white painted finish |
| Budget | Premium | Cost-effective |
| Best for | Salt air, wash-down areas, long service life | Campuses, parking lots, utility and telecom roll-outs |
Working near the ocean? Read our guide to marine-grade outdoor enclosures.
Pole, Wall or Floor Mount?
- Pole mount: best for CCTV, traffic, Wi-Fi and small cell sites where ground space is limited. Pole mount brackets are sold separately.
- Wall mount: for building exteriors, rooftops and parking structures; wall-mount capable models ship with wall brackets.
- Floor (pad) mount: for 26U to 42U cabinets on a concrete pad, using the pre-drilled base.
How to Choose the Right Outdoor Telecom Cabinet
- Count rack units for today's equipment and add 20 to 30 percent for growth.
- Check depth: take your deepest device and add 4 to 6 in for cables and airflow.
- Estimate heat load: low loads can use vents or fan modules; hot climates or dense PoE and servers need an enclosure air conditioner.
- Match the environment: stainless steel for coastal or corrosive sites, galvanized for most other locations.
- Plan the mount: pole, wall or concrete pad, plus cable entry and grounding.
Common Applications
- Telecom, 5G small cell and fiber (OSP) distribution
- Outdoor IDF cabinets for campuses, stadiums and industrial parks
- CCTV, access control and perimeter security
- Traffic, ITS and smart city equipment
- Utilities, SCADA, solar farms and EV charging networks
FAQ: Outdoor Network and Telecom Cabinets
What does IP66 mean for an outdoor cabinet?
IP66 means the enclosure is dust-tight (6) and protected against powerful water jets from any direction (6). Learn more in What does IP66 rated mean?
Is IP66 the same as NEMA 4?
They are similar for dust and water-jet protection, but they are different standards. NEMA ratings include extra criteria, so IP66 and NEMA 4 are comparable rather than identical.
Do I need an air conditioner in my outdoor cabinet?
If the site sees high ambient temperatures, direct sun or a high equipment heat load, a Climate Series cabinet with A/C is recommended. Lower heat loads can often be managed with fan modules.
How do I prevent condensation inside an outdoor enclosure?
Keep the cabinet sealed, manage temperature swings and use cooling with dehumidification where needed. See how to stop condensation.
Can STURDX customize an outdoor cabinet?
Yes. Rear doors and custom width or depth can be requested; custom orders typically ship in about 4 to 6 weeks. Contact us with your requirements.
What equipment fits inside?
Any 19-inch rack equipment such as switches, routers, patch panels, fiber enclosures, NVRs, PDUs and UPS units, plus shelves for non-rackmount devices.